OP-AMP TEST 18 February 2006 ** Dose 500 Gray Run 16 - file: PIF2006_02_18h03m10s35.flw 02:55 SCAN TLC2252_1 Start 4.19 min 4.18 max 4.19 end of scan 03:12 03:13:27 jump in the measurement when CFC card was connected. (the power supply comes from inside the bunker) Run 17 - file: PIF2006_02_18h03m38s00.flw 03:25 SCAN TLC2252_2 Start 4.21 min 4.207 max 5.02 end of scan 03:38 Run 18 - file: PIF2006_02_18h03m54s35.flw 03:45 SCAN LT1490_1 Start: 4.24 min jumps down @ 170, 190 ... end of scan 03:54 Run 19 - start and stop Run 20 - file: PIF2006_02_18h04m20s41.flw 03:58 SCAN TLC2252_3 Start 4.205 max 4.80 (error in "Data Flow" file with wrong comment about type) 04:03 pause at 100 Gy. 04:05 start at 145 Gy stop again, 04:08 start 04:12 pause at 306 Gray 04:18 Start ---- added 10 KOhm 04:19 END at 360 Gray Run 21 - file: PIF2006_02_18h04m41s44.flw (the 10K is still connected) 04:29 SCAN TLC2252_4 Start 4.204 04:32 pause 105 Gray 04:33 Start ---- continuously increasing 04:40 END @300 Gray, >4.9