20040623 *_labADC?: first measurements in lab, with short cables and oscilloscope. *1812_ADC1: 100 points in logarithmic scale from 12 mA to 1 microA; strange measure after 10 micron external amplifier switching. ***Removed switching***.Peaks below 10 microA. *1839_ADC1: 100 points in logarithmic scale from 12 mA to 1 microA. No peaks. *1844_ADC1: 100 points in logarithmic scale from 12 mA to 1 microA. Two peaks of 209 counts at 2.4 and 4.2 microA. *1852_ADC1: 100 points in logarithmic scale from 12 mA to 1 microA. Three peaks of 207-211 counts at 2.0-8.9 microA. *1903_ADC2: 100 points in logarithmic scale from 12 mA to 1 microA. One 'negative" peak of 6 counts at 4.2 microA. *1934_ADC2: 100 points in logarithmic scale from 12 mA to 1 microA. One 'negative" peak of 17 counts at 27 microA. *1944_ADC2: 100 points in logarithmic scale from 12 mA to 1 microA. 20040626 Beam Condition: 60.43 MeV, Flux ~3 10^8 *1814_ADC2irr: not yet irradiated. *1817_ADC2irr: irradiated. *1825_ADC2irr: 220 Gy, higher low limit *1828_ADC2irr: stop irradiation @ 285 Gy. 1060 counts at low voltage. *1837_ADC1irr and *1838_ADC1irr: not yet irradiated *1840_ADC1irr: start irradiation *1846_ADC1irr: 190 Gy, start degradation, 100 counts *1847_ADC1irr: 218 Gy , 535 count *1848_ADC1irr: stop irradiation @ 218 Gy CAPACITORS FOR IC 1 and 2 irradiated for 285 + 218+3= 506Gy