lObservation Time-Windows
§Adding newest data
§Subtracting oldest data
§Capacity of FIFO
lTh & W table values depending on:
§Beam Energy
§Ion. Chamber Position
§Time-Window
§Read 2 values from a table of 576 values
lComparisons on chip
§96
times in parallel (6 TimeWind.*16 Ion)